Kilpiarvot ja standardit

 

International standard IEC 34-1 defines 8, IEC 60034-1 10, different stampings for different ways to use a motor: S1, S2… S10. These are named as follows:

 

S1 - Continuous running duty. Stamp: S1.

S2 - Short-time duty. Stamp e.g.: S2 10 min. Thermal equilibrium not reached. De-energised rest to reach the coolant temperature within 2 K.

S3 - Intermittent periodic duty. Stamp e.g.: S3 25%. Identical cycles. The starting current may not significantly affect the temperature rise.

S4 - Intermittent periodic duty with starting. Identical duty cycles, significant starting time, constant load, de-energized at rest. FI = (JL+JM)/JM. Stamp e.g.:           

                  Image Added   

S5 - Intermittent periodic duty with electric braking. This is like S4 but with electric brake.

S6 - Continuous-operation periodic duty. Identical cycles, also the idling power is observed, no time in rest.

S7 - Continuous-operation periodic duty with electric breaking. Like S6 but each cycle includes also electrical breaking. Stamping like in S4.

S8 - Continuous-operation periodic duty with related load/speed changes. Stamping example:

                  Image Added

S9 - Duty with non-periodic load and speed variations. The duty includes frequently applied overloads that may greatly exceed the reference load (Pref is appropriately based on duty type S1).

S10 - Duty with discrete constant loads and speeds. Duty consists of a specific number of discrete values of load (and if applicable, speeds), each for sufficient time to allow the machine to reach thermal equilibrium. The parameter TL expresses the thermal life expectancy of the insulation system as compared to the value of duty type S1. Stamping example:

                      S10: p/Δt = 1,1/0,4; 1/0,3; 0,9/0,2; r/0,1 TL = 0,6

 

Alla olevassa kuvassa on esitetty millainen mottorin arvokilpi voisi olla. Huomaa, että moottori vastaa luokkaa S1.

                        Image Added

Seuraavassa kuvassa on esitetty mahdoliset kytkentätäavat. Notice, that in both connections the voltage over the windings is 400 V and the current through is 3.8 A. The decimal comma is used in the plate and the pictures, instead of decimal point, according to the IEC standard.

                                                  Image Added

The nominal electrical power can be calculated as shown here:

                      Pelectric = sqrt(3)VIcosφ = sqrt(3)·400V·6.6A·0.82 = 3750 W.

With the nominal load the efficiency is:

                      η = Pshaft/Pelectric = 3000W/3750W = 0.80 = 80 %.

In the USA, NEMA-standards are followed.

 

Katso: IEC 60034-1