Diabetes is a chronic autoimmune disease, which make the body of the sufferer unable to produced or properly use up insulin. In the United

Anchor
_GoBack
_GoBack
States of American, there are over 30.3 million sufferers and it is the seventh leading cause of death and number 1 leading cause of kidney failure, lower limb amputations and adult-onset of blindness. Estimated direct and indirect cost of treatment was 245 billion dollars in 2012 an average cost of between $13,700 to $7,900 for each patient (Centers for Disease Control and Prevention, 2017.) While in Europe, there are estimated 53 million adults living with diabetes and the cost of treatment -excluding the complications such as kidney failure, heart disease, amputation etc. - is estimated to cost 9 % of total health expenditure of European countries (International Diabetes Federation Europe & Primary Diabetes Care Europe, 2011.) There are currently no known cures for diabetes diseases. Therefore, proper monitoring of the level of glucose in the blood is fundamental, if the patient is to stay healthy and avoid life-threatening complications that might result from uncontrolled diabetes disease (CDC, 2017.) According to Ginsberg Barry H (2007) blood glucose monitoring is of paramount importance for four reasons: (a) it informs the patient of how much medication (self-adjust insulin) is needed; (b) it provides rough data to the patient on how much they are doing to avoid for example hypoglycemia; (c) it reminds them to change their behavior behaviour to meet their medical need; and (d) it provides data for health care providers to make necessary adjustment of mediation regimen of the patient. The severity of the disease, its prevalence and estimated effects across the globe, highlighted our keen interest in the disease and one of the most modern tools to control the impact.

...

  • The transmitter range for the Bluetooth connectivity is only about 3m so the receiver must be in that range to maintain the connection with the transmitter.
  • Transmitter's battery lasts only about 3 months and new one must be ordered every time through Dexcom web page. This can cause problems for the user if he/she forget to order new transmitter on time.
  • If user's phone runs out of battery power, there will be no way to receive data from the transmitter. Also, the Bluetooth connection consumes a lot of phone battery.
  • Bluetooth connection is not so reliable.
  • Still fingertip blood sample need to be taken and calibrated every 12 hours.

...

Future views


According to David Rodbard (2017) the use of continuous glucose monitoring devices are now reliable in reducing the hypoglycemia and hyperglycemia. Furthermore, they have improved patients quality of lives across wide range of patient population. Continuous glucose monitoring is having a remarkable success in reducing HbA1c glucose level. Real-time glucose monitoring (RT-CGM) provides diabetes management tools for patient with type 1 and type 2 diabetes by giving them valuable information to make and sustain healthy lifestyle choices. The provision of RT-CGM every 5 minutes for patient with type 2 diabetes who are generally not good at monitoring their diabetes level. This patient group using RT-CGM were able to reduce the time they spent-on hyperglycemia (23%), hypoglycemia (21%) and they have reduced level of HbA1c compare to patient using Self-monitoring blood glucose. Glycemic variability has adverse effects on: endothelial tissue function, cognitive functions, retinopathy and cardiovascular system but with Dexcom 5G constant RT-CGM, these dangers can be avoided and minimized. On the disadvantage side, Dexcom 5G requires twice daily calibrations and alarm fatigue can develop which lead to some users completely ignoring the warnings (

Anchor
_Hlk494481228
_Hlk494481228
Fonda S., J, Salkind S., Vigersky A. R. Walker M. S. 2012.) The increase in the level of accuracy, user friendliness, reliability and the ability to share, monitor data. These highlight the future prospects RT-CGM which some health care providers see as the "artificial pancreas systems" have come to stay (
Anchor
_Hlk494483445
_Hlk494483445
Balo Andrew K, Bhavaraju Naresh C., Hughes J., Vanslyke Stephen J., & Welsh John B. 2017.)
In conclusion, we strongly believe most of the studies given above that the Dexcom G5 Mobile CGM is a reliable device. Which is going to further improve the relationship between health care providers and patients. By providing continuous real-time raw data to health care providers the connection between patient and care provider will be strengthen. Dexcom G5 is the pacesetter in taking patients and nurses into the future in a new direction of artificial pancreas, providing real-time solution to diabetes disease.

...